| LUMEN OUTPUT |
|
(1) Lamp - 700 lumens (2) lamps - 350 lumens per lamp |
| LAMPS OPERATED |
|
Most 2'-8' single, bipin T8 & T12, long compact, HO or VHO fluorescent lamps |
| EMERGENCY OPERATION |
|
90 Minutes |
| PRODUCT DESCRIPTION |
|
The I-48 Fluorescent Emergency Ballast allows the same fixture to be used for both normal and emergency operation. In the event of a power failure, the I-48 switches to the emergency
mode and operates one or two of the existing lamps for 90 minutes. The unit contains a battery, charger, and inverter circuit in a single can. The I-48 can be mounted in the wireway or on top of the fixture, and is UL Listed for retrofit
applications. The I-48 can be used with most 2'-8' lamps, with a total initial output of up to 700 lumens for one or two lamps.
|
|
||||
| AVERAGE LUMEN RATINGS | ||
| Lamp | 1 Lamp | 2 Lamps |
| F17 T8 | 450 | 650 |
| F32 T8 | 700 | 675 |
| 8' T8 (FO96) (59W) | 675 | |
| F20 T12 | 390 | 650 |
| F40 T12 | 660 | 650 |
| 8' T12 (F96T12) (60W) | 650 | |
| 40W Long Compact | 600 | |
| 50W Long Compact | 625 | |
| 55W Long Compact | 650 | |
| 20W Circline | 390 | |
| 22W Circline T9 | 400 | |
| 22W Circline T5 | 425 | |
| 40W Circline T8 | 650 | |
| 40W Circline T5 | 650 | |
| 55W Circline T5 | 650 | |
| FEATURES | |
|
U.L. and C.U.L. Listed Will cold start and operate all specified lamps Long-life high-temperature recyclable Ni-Cad battery Galvanized steel case 90-minute emergency operation Dual voltage 120/277V, 60Hz Time Delay Enhancement Open Circuit Isolation 5-year warranty. See Warranty Page for details. Includes test switch/charge indicator accessory kit DL model suitable for use in enclosed and gasketed fixtures I-48-EM-A Remote Mounting Option Meets or exceeds all National Electrical Code and Life Safety Code Emergency Lighting Requirements International Voltage and Damp Location Models available |
|
| DIMENSIONS |
|