top banner www.iotaengineering.com
   ILB-SL-CP08-HE Slimline LED Emergency Driver Specification Sheet in PDF format Installation Manual in PDF format Wiring Diagrams
IOTA ILB-SL-CP08-HE CEC-Compliant Emergency Driver LED Operation
8 Watt LED load @ 10-60 Vdc Nominal*

Output
8 Watts (Constant)

Emergency Operation
90 Minutes

Product Description
The ILB-SL-CP08-HE from IOTA is a UL Listed LED emergency driver for field or factory installation that allows the same LED fixture to be used for both normal and emergency operation. In the event of a power failure, the ILB-SL-CP08-HE switches to the emergency mode and operates the existing fixture for 90 minutes. The unit contains a battery, charger, and converter circuit in a single slim profile enclosure for installation within the channel space or wireway. The ILB-SL-CP08-HE will operate an LED array load at 8 watts with constant power at a rated output voltage of 10V-60V. The patented Constant Power design of the ILB-SL-CP08-HE maintains the output wattage to the LED array even as the system voltage diminishes, resulting in a constant illumination level for the entire emergency runtime. The ILB-SL-CP08-HE features high-efficiency performance and complies with CEC efficiency requirements.

Product Description

Input Voltage: (Universal) 120-277Vac, 50/60 Hz

Input Rating: 2.9 Watts (max)

Output Voltage* 10-60 Vdc Class 2 Compliant

Output Current 0.8A (@10Vdc) - 0.13A (@60Vdc)

Output Power 8 Watts (constant)

Max. AC Driver Output Current 3Adc

Power Factor ≥ 0.9 @ 120VAC**

Surge Protection Meets ANSI/IEEE C62.41.2-2002

Emergency Operation 90 minutes

Operating Temp 0° to 55° C

THD < 15% (@ full charge)

Battery


High Temp Nickel-Cadmium
24 Hour Recharge
7-10 Year Life Expectancy

Weight 2.25 lbs

Approval







cUL Listed for factory and field installation
California Energy Commission (CEC)
*Max. output voltage in emergency mode is 58.5 with +tolerance of 1.5 volts. **PF ≥ 0.75 @ 277VAC

   PRODUCT ADVANTAGES

  • High Efficiency Performance meets CEC battery charger
    efficiency standards (CEC-400-2014-009-CMF)


  • UL and cUL Listed for field installation

  • Patented True Constant Power Design maintains emergency illumination through 90-minute runtime with no light degradation

  • Slim Profile housing allows integral installation within restrictive and narrow channel spaces of strip and troffer fixtures.

  • Two-wire universal AC input

  • Self-sensing output voltage operates various product types, reducing product SKUs for emergency options

   FEATURES


  • UL 924 Listed for U.S. and Canada

  • UL 1310 Certified, Output Class 2 Compliant

  • Long life high temperature recyclable Ni-Cad battery

  • Galvanized steel case

  • Includes single-piece TBTS test switch and charge indicator accessory

  • For use with switched and unswitched fixtures

  • 5-year warranty. See Warranty Page for details.

  • Meets or exceeds all NEC, IBC, and Life Safety Code Emergency Lighting Requirements

  • Rated for use in Plenum, Damp Location, Recessed Type IC, and Enclosed and Gasketed Luminaires

  • RoHS Compliant

  • Patented. Visit www.iotaengineering.com/patents for more details.

Emergency Lumen Performance - ILB-CP08

Approx. Luminaire Efficacy Minute 1 Minute 45 Minute 90
100 lumens/watt 800 800 800
110 lumens/watt 880 880 880
120 lumens/watt 960 960 960
130 lumens/watt 1040 1040 1040


Dimensions

22.17" x 1.18" x 1.18" (Mounting Center: 21.77 x 0.67")