I42 Emergency Ballast

Emergency Ballast for 4-Pin LED Retrofit (TLED) and Compact Fluorescent Luminaires

By IOTA

  • Overview
  • Specifications
The I42 from IOTA Engineering is a UL Listed fluorescent emergency ballast that allows the same fixture to be used for both normal and emergency operation. In the event of a power failure, the I42 switches to the emergency mode and operates one or two of the existing lamps for 90 minutes. The unit contains a battery, charger, and inverter circuit in a single can. The I42 utilizes AC output to ensure compatibility with new lamp technologies, and features lamp selector leads for optimizing light output for designated lamp types.
Initial Lumen Output
  • 650 Lumens
Lamps Operated
  • Select LED Retrofit Tubes
  • (1) 10W-42W 4-Pin Compact
  • (2) 10W-18W 4-Pin Compact
  • (1) 18W-35W Long Compact
Features
  • AC output for compatibility with low mercury content amalgam lamps
  • Time Delay feature for compatibility with End-of-Lamp-Life circuitry
  • Open Circuit Isolation protects unit when load is absent
  • Will cold start and operate all specified lamps
  • Long life high temperature recyclable Ni-Cad battery
  • Six mounting configurations available
  • Galvanized steel case
  • Includes test switch and charge indicator accessory kit
  • For use with switched or unswitched fixtures
  • Lamp selector leads optimize light output for designated lamp type
  • Rated for use in damp locations, plenum, and enclosed and gasketed fixtures
  • Meets or exceeds all NEC, IBC, and Life Safety Code Emergency Lighting Requirements
  • RoHS Compliant
Read More
Read Less
Product Type Emergency Ballast
Voltage Rating 120/277
Frequency 60HZ
Max. Operating Temp. 50
Min. Operating Temp. 0
Battery Run Time 90 min
Battery Chemistry Type NiCd
Battery Recharge Time 24 hours
Battery Activation Unit Connector
Life Safety Testing Manual Testing
Regulatory Listing C-UL-US, NFPA 101
Compliance Listing ROHS
Environmental Listing Damp Location
Series I42

Read More Read Less

  • Suggested Replacement Products

Product Information

  • Spec Sheets

    Document Type Document Title Description Updated View
    SPEC SHEET I42 Specifications Specification Sheet for IOTA I42 Models (Series AC) 2/17/2020 View
  • Technical Documents (e.g. Instruction Sheets, MSDS, CAD)

    Document Type Document Title Description Updated View
    Installation Instructions A Mounting Style I42 A - Dual Flex Mounting Style 9/19/2019 View
    Installation Instructions B Mounting Style I42 B - Integral Mounting Style 9/19/2019 View
    Installation Instructions J Mounting Style I42 J - Junction Box Mounting Style 9/19/2019 View
    Installation Instructions R Mounting Style I42 R - Reflector Mounting Style 9/19/2019 View
    Installation Instructions RJ Mounting Style I42 RJ - Reflector and Junction Box Mounting Style 9/19/2019 View
    Installation Instructions TM Mounting Style I42 TM - Top Mount Mounting Style 9/19/2019 View
    Material Safety Data Sheet MSDS for nickel-cadmium drivers and ballasts Safety Data Sheet for Ni-Cad emergency battery component 5/12/2021 View
    Wiring Diagram (DWG) One Lamp Rapid Start Ballast DWG Format - Connections to a one lamp luminaire with a rapid start ballast 7/7/2020
    Wiring Diagram (DWG) Two Lamp (One EM Lamp) Rapid Start Ballast DWG Format - Connections to a two lamp luminaire (one emergency lamp) with a rapid start ballast 7/7/2020
    Wiring Diagram (DWG) Two Lamp (Two EM Lamps) Rapid Start Ballast DWG Format - Connections to a two lamp luminaire (two emergency lamps) with a rapid start ballast 7/7/2020
    Wiring Diagram (PDF) One Lamp Rapid Start Ballast PDF Format - Connections to a one lamp luminaire with a rapid start ballast 7/7/2020 View
    Wiring Diagram (PDF) Two Lamp (One EM Lamp) Rapid Start Ballast PDF Format - Connections to a two lamp luminaire (one emergency lamp) with a rapid start ballast 7/7/2020 View
    Wiring Diagram (PDF) Two Lamp (Two EM Lamps) Rapid Start Ballast PDF Format - Connections to a two lamp luminaire (two emergency lamps) with a rapid start ballast 7/7/2020 View
  • BIM Models (Revit)

  • Utility Rebate Search

  • Replacement Parts

  • Confidential Documents

  • Marketing Material (e.g. Brochures, Sell Sheets, FAQs, )

    Document Type Document Title Description Updated View
    Sell Sheet IOTA Contractor Insider_LED-Retrofit_A and C.pdf Using IOTA Emergency Drivers and Series AC Emergency Ballasts for LED Retrofit projects 3/9/2021 View
  • Need Product Assistance? (e.g. How to Buy, Technical Support, Warranty)

    How to Buy

    The IOTA products are primarily sold through a network of agents and distributors across North America.

    •  Find an Agent or Distributor

    •  Request a Call


    Technical Support

    The IOTA technical team is dedicated to providing outstanding product support. Please click on the appropriate link below,
    or feel free to call us at 855.363.9527.

    •  FAQs

    •  Technical Library

    •  Email Us


    Warranty

    Please click on the appropriate link below to learn more about Acuity Brands terms & conditions and product warranty options.

    •  Review Terms & Conditions or Product Warranties

    •  IOTA Warranty Replacements & Stock Returns