ProductItem
ProductItem

IISCN3P Three-Phase Central Inverters

4.8kVA to 50kVA Three Phase Emergency Inverter Systems for Canada
  • Overview
  • Specifications
IOTA IISCN3P Series Inverter Systems are cUL Listed 3-phase emergency lighting central inverters designed for Canada. They feature a 3-phase sine wave output that provides power to designated emergency lighting fixtures for a minimum of 30 minutes, 60 minutes, or 120 minutes in the event of a loss of normal power. In a power loss situation, the IISCN3P Series will supply 4.8kVA to 50kVA of emergency power from the battery supply at 2ms transfer time.

The IOTA IISCN3P Series works in conjunction with any lighting load type and is capable of running normally-on or normally-off designated circuits in the emergency mode. The IISCN3P Series is ideal for providing emergency power to extensive lighting arrangements that utilize multiple lamp and fixture types.

IOTA IISCN3P Series inverters automatically conduct monthly and annual tests for operation readiness and log the test results for reference as needed.

The IISCN3P Series features a durable front-access NEMA Type 1 steel cabinet design and is backed a standard 1-year warranty.
Read More
Read Less
Product Type Emergency Inverter
Voltage Rating 120, 208, 277, 480
Frequency 60HZ
Load Voltage Rating 120VAC, 208VAC, 277VAC, 347VAC, 480VAC
Output Power 10000 VA, 12500 VA, 16700 VA, 24000 VA, 33000 VA, 40000 VA, 4800 VA, 50000 VA, 6000 VA, 8000 VA
Max. Operating Temp. 30
Min. Operating Temp. 20
Battery Run Time 120 min, 30 min, 60 min
Battery Chemistry Type Lead Acid
Life Safety Testing Self Diagnostics, Self Test
Regulatory Listing CSA, cUL
Series IISCN3P

Read More Read Less

  • Suggested Replacement Products

Product Information

  • Spec Sheets

    Document Type Document Title Description Updated View
    Spec Sheet IISCN3P 3-Phase Inverter Specification Sheet Spec sheet for IOTA IISCN3P three-phase Canada Emergency Inverters 8/3/2023 View
  • Guideline Specifications

  • Technical Documents (e.g. Instruction Sheets, MSDS, CAD)

    Document Type Document Title Description Updated View
    Installation Instructions IISCN3P Installation Guide - Large Models (English) Installation Guide for IISCN3P models: 24kW-50kW (20.4kW-42.5kW 120M runtime) 5/9/2022 View
    Installation Instructions IISCN3P Installation Guide - Large Models (French) Installation Guide for IISCN3P models: 24kW-50kW (20.4kW-42.5kW 120M runtime) 5/9/2022 View
    Installation Instructions IISCN3P Installation Guide - Small Models (English) Installation Guide for IISCN3P models: 4.8kW-16.7kW (4.08kW-14.2kW 120M runtime) 5/9/2022 View
    Installation Instructions IISCN3P Installation Guide - Small Models (French) Installation Guide for IISCN3P models: 4.8kW-16.7kW (4.08kW-14.2kW 120M runtime) 5/9/2022 View
    Material Safety Data Sheet MSDS - VRLA Batteries Material Safety Data Sheet for the VRLA Batteries 5/13/2021 View
    Technical Bulletins IISCN3P Weights and Dimensions Weights and Dimensions Reference Sheet for IISCN3P Models 5/3/2022 View
    User Manual IISCN3P User Guide - Large Models (English) User Guide for IISCN3P models: 24kW-50kW (20.4kW-42.5kW 120M runtime) 5/9/2022 View
    User Manual IISCN3P User Guide - Large Models (French) User Guide for IISCN3P models: 24kW-50kW (20.4kW-42.5kW 120M runtime) 5/9/2022 View
    User Manual IISCN3P User Guide - Small Models (English) User Guide for IISCN3P models: 4.8kW-16.7kW (4.08kW-14.2kW 120M runtime) 5/9/2022 View
    User Manual IISCN3P User Guide - Small Models (French) User Guide for IISCN3P models: 4.8kW-16.7kW (4.08kW-14.2kW 120M runtime) 5/9/2022 View
  • Revit Component Files (Non-Illuminated)

  • Utility Rebate Search

  • Replacement Parts

  • Confidential Documents

  • Marketing Material (e.g. Brochures, Sell Sheets, FAQs)

    Document Type Document Title Description Updated View
    Brochures IISCN Factory Startup and Training Factory Startup and On-Site Training Services Available for IISCN and IISCN3P Inverters 2/24/2022 View
    Catalogs IIS Central Inverter Options Reference Guide Explore the available options for IIS Central Inverters to fit your emergency egress application 11/7/2023 View
    Sell Sheet IOTA IISCN Series Inverters for Canada Sell Sheet for IOTA IISCN and IISCN3P Inverter Solutions for Canada 4/8/2025 View
  • Need Product Assistance? (e.g. How to Buy, Technical Support, Warranty)

    How to Buy

    The IOTA products are primarily sold through a network of agents and distributors across North America.

    •  Find an Agent or Distributor

    •  Request a Call


    Technical Support

    The IOTA technical team is dedicated to providing outstanding product support. Please click on the appropriate link below,
    or feel free to call us at 855.363.9527.

    •  FAQs

    •  Technical Library

    •  Email Us


    Warranty

    Please click on the link below to learn more about terms & conditions and product warranty options. 

    •  Review Terms & Conditions or Product Warranties

Other People Have Also Viewed