By IOTA
Product Type | Emergency Inverter |
Voltage Rating | 120/277 |
Frequency | 60HZ |
Load Voltage Rating | 120VAC, 277VAC |
Output Power | 375 Watts |
Max. Operating Temp. | 30 |
Min. Operating Temp. | 20 |
Battery Run Time | 90 min |
Battery Chemistry Type | Lead Acid |
Life Safety Testing | Manual Testing |
Regulatory Listing | UL |
Compliance Listing | ROHS |
Series | IIS |
Read More Read Less
Suggested Replacement Products
Spec Sheets
Document Type | Document Title | Description | Updated | View |
|
|
---|---|---|---|---|---|---|
SPEC SHEET | IIS 375 I Specifications | Specification Sheet for IIS 375 I Models | 3/23/2022 | View |
|
|
Technical Documents (e.g. Instruction Sheets, MSDS, CAD)
Document Type | Document Title | Description | Updated | View |
|
|
---|---|---|---|---|---|---|
Installation Instructions | IIS 375 I DR Manual | IIS 375 I DR (Dimming Relay) Model | 2/22/2021 | View |
|
|
Installation Instructions | IIS 375 I Manual | IIS 375 I (Standard) Model | 2/22/2021 | View |
|
|
Material Safety Data Sheet | MSDS-HY_Sealed-Lead-Acid-Battery.pdf | Safety Data Sheet for Sealed Lead Acid Battery component | 5/13/2021 | View |
|
|
Technical Bulletins | IOTA Contractor Insider_Extending-Runtimes.pdf | IOTA offers different ways to achieve extended runtimes for 120-minute emergency applications | 7/23/2021 | View |
|
|
Wiring Diagram | (DWG) Dimming Relay (DR) Model | DWG Format - Connections to an emergency load with a 0-10V dimming control | 7/9/2020 | View |
|
|
Wiring Diagram | (DWG) Dimming Relay (DR) Models - Without Circuit Breaker | DWG Format - Connections to an emergency load with a 0-10V dimming control (legacy models - no internal circuit breaker) | 7/9/2020 | View |
|
|
Wiring Diagram | (DWG) Typical Installation | DWG Format - Connections to an emergency load with an optional switched input | 7/9/2020 | View |
|
|
Wiring Diagram | (DWG) Typical Installation - Without Circuit Breaker | DWG Format - Connections to an emergency load with an optional switched input (legacy models - no internal circuit breaker) | 7/9/2020 | View |
|
|
Wiring Diagram | (PDF) Dimming Relay (DR) Model | PDF Format - Connections to an emergency load with a 0-10V dimming control | 7/9/2020 | View |
|
|
Wiring Diagram | (PDF) Dimming Relay (DR) Model - Without Circuit Breaker | PDF Format - Connections to an emergency load with a 0-10V dimming control (legacy models - no internal circuit breaker) | 7/9/2020 | View |
|
|
Wiring Diagram | (PDF) Typical Installation | PDF Format - Connections to an emergency load with an optional switched input | 7/9/2020 | View |
|
|
Wiring Diagram | (PDF) Typical Installation - Without Circuit Breaker | PDF Format - Connections to an emergency load with an optional switched input (legacy models - no internal circuit breaker) | 7/9/2020 | View |
|
|
BIM Models (Revit)
Document Type | Document Title | Description | Updated | View |
|
|
---|---|---|---|---|---|---|
BIM Models | IIS 375 I.rfa | IIS 375 I | 12/16/2021 | View |
|
|
Utility Rebate Search
Replacement Parts
Confidential Documents
Marketing Material (e.g. Brochures, Sell Sheets, FAQs, )
Document Type | Document Title | Description | Updated | View |
|
|
---|---|---|---|---|---|---|
Application Guide | Contractor Insider - Remote Mounting Guidelines | A Quick Reference for knowing remote mounting capabilities of emergency lighting solutions. | 10/21/2021 | View |
|
|
Application Guide | IIS Mini and Micro Inverter Remote Mounting | Guidelines for remote mounting IOTA IIS mini and micro-inverter systems | 10/21/2021 | View |
|
|
Application Guide | Tech App_Mini-Inverters and Outdoor Egress.pdf | Understand How IIS Mini Inverters Solve Unique Outdoor Emergency Lighting Challenges | 7/23/2021 | View |
|
|
Need Product Assistance? (e.g. How to Buy, Technical Support, Warranty)
How to Buy
The IOTA products are primarily sold through a network of agents and distributors across North America.
• Find an Agent or Distributor
Technical Support
The IOTA technical team is dedicated to providing outstanding product support. Please click on the appropriate link below,
or feel free to
call us at 855.363.9527.
• FAQs
• Email Us
Warranty
Please click on the appropriate link below to learn more about IOTA terms & conditions and product warranty options.
• IOTA Emergency Products with Batteries
• IOTA Emergency Control (ALCR) Devices
• IOTA DLS Battery Chargers and Power Converters
• IOTA Warranty Replacements & Stock Returns
Please provide as much feedback as possible during the pilot phase, CLICK HERE.
SKU data not available, please contact your local agent.
{{getMinimumDisplayedIndex()}} - {{getMaximumDisplayedIndex()}} of {{filteredStockedProducts.length}} results
No Locations Could Be Found.
This catalog # is not available at any location at this time. Inventory is replenished daily, please check back or contact your local sales representative or agency further details.
Available | Est. Ship Date | Location | In Transit |
---|---|---|---|
{{loc.QUANTITY > 0 ? loc.QUANTITY : 0}} | {{loc.ESTIMATED_SHIP_DATE}} | {{loc.LOCATION}} | {{loc.IN_TRANSIT_QUANTITY}} |